OPC-P6 Portable Oil Particle Counter
OVERVIEW
OPC-P6 Portable Oil Particle Counter adopts Laser Extinction Technology, is designed to measure the particles' size and quantity in oil liquid. It is Suitable for tests of pollution degree of solid particles in hydraulic oil, lubricating oil, fire resistant oil, insulating oil, turbine oil, organic liquid and polymer solution, etc. So our instrument can be used in aviation, spaceflight, electric power, petroleum, chemical industry, transportation, port, metallurgy, machinery, automobile manufacturing and many other fields.4.1 Power Choice: External power or Battery.
FEATURES
- The light blocking (shading) test principle specified by the International Hydraulic Standards Committee
- High-precision laser sensor, wide test range, stable performance, low noise, high resolution
- High-precision bidirectional plunger pump sampling method, adjustable injection speed, high sampling volume accuracy
- The pipeline is made of 316L and PTFE materials, which are corrosion-resistant and can meet the detection requirements of various organic solvents and oils.
- For laboratory or on-site measurement, optional pressure reducing device for online high-pressure measurement
- Can be connected to an external pressure chamber to form positive/negative pressure, enabling detection of high viscosity samples and negative pressure degassing of samples
- A variety of sampling containers such as standard sampling bottles and sampling cups can be used, or they can be directly connected to the hydraulic system for online testing to meet the testing requirements of different industries
- Built-in multiple calibration curves, compatible with all commonly used domestic and foreign standards for calibration
- Automatic calibration, manual calibration and half-count calibration are available
- Built-in GJB-420A, GJB-420B, NAS1638, GB/T14039, ISO4406, SAE4059cpc, SAE4059F, SAE749D, Г OCT17216 , QC/T29104, JB/T9737, DLT432, HH005-2018 and more than ten commonly used standards. One test can give the data results under all built-in standards
- Supports custom standard testing and can set up 64 detection channels at the same time according to customer needs
- 1000 particle size channels can be set to facilitate particle size analysis
- Built-in data analysis system, which can automatically determine the sample grade according to the standard, and has the function of automatic data processing and printing
- 7-inch color touch screen operation, Chinese and English input, free switching of language interface, with preset, input, modification, storage, upload functions, convenient and fast operation
- You can set up multiple user login accounts at will, add new users, set permissions, and delete old users.
- Optional tablet computer control, win10 operating system, can edit personalized signature for operators
- With RS232 interface, it can be connected to a computer or laboratory platform for data processing, and can also use USB for data storage
- Built-in lithium battery, suitable for field operations, can be used without external power supply
- Embedded design , high-strength shell, easy to carry, suitable for all kinds of engineering machinery
APPLICATION SCENES
OPC-P6 can be widely used in aviation, aerospace, electric power, petroleum, chemical industry, transportation, port, metallurgy, machinery, automobile manufacturing and other fields.
PRODUCT PARAMETERS
Light source | semiconductor laser | Particle size range | 0.8-600μm ( calibrated according to ACFTD calibration 1~100μm or ISO MTD calibration 4~70μm(c) ) | Detection channels | 64, particle size can be set arbitrarily | Sampling volume | 0.2-1000ml | Sampling accuracy | better than ±1% | Sampling speed | 5-80mL/min | Cleaning speed | 5-80mL/min | Cleaning volume | can be set between 0ml and 90ml | Counting accuracy | error less than ±5% | Resolution | ≤10% | Repeatability | RSD<2% | Limit coincidence error | 12000-40000 particles/mL | Temperature acquisition (optional) | -40~100ºC Accuracy ±0.5ºC | Moisture (optional) | Water activity collection | 1~100%RH; Accuracy | ±1%RH | Absolute water content | 1~360ppm; Accuracy ±10ppm | Viscosity (optional) | 0.5~50 0 cSt Accuracy ±2% | Offline detection viscosity | ≤100cSt (optional pressure bottle sampler with maximum viscosity up to 400cSt) | Pressure range | low pressure 0-0.6MPa, high pressure up to 42MPa (optional pressure reducing valve) | Online detection interval | arbitrarily set | Instrument screen size | 7 inches | Tablet size | 10 inches (optional) | Tablet computer system | Windows 10 Professional Edition system TYPE-C to DB9 data cable connected to the instrument serial port | Flash | 64GB | RAM | no less than 4GB DDR3L | Test sample temperature | 0ºC~80ºC | Working temperature | -20ºC~60ºC | Storage temperature | -30ºC~80ºC | Power supply | AC100-240V, 50/60Hz | Battery capacity | 5200mAh | Battery operating time | 6-8 hours | Dimensions | 420 *326 * 182mm | Weight | 9 kg |     |