UVOZ-3000 Exhaust Ozone Detector
According to the foreign light cell technology design pressure-resistant, impact-resistant independent light cell structure, the gas flow, pressure, and flow rate remain unchanged during the operation of the calibration zero, to prevent the impact of airflow on the calibration zero, no need to close the ozone intake can complete the calibration zero operation, to ensure that the equipment can operate continuously 24 hours a day.
The exhaust ozone detector calculates the current ozone concentration value by measuring the change in light signal intensity before and after the absorption of UV light by ozone. The equipment uses a dual-optical UV light source system with a lamp intelligent management system inside, which can make the UV lamp quickly reach the measurement state after powering on. Using foreign separated light cell technology, the equipment has the characteristics of no leakage, high-pressure resistance, high flow sampling gas impact resistance, easy cleaning, easy maintenance, simple operation, and low cost of use.
It is mainly used for the continuous detection of ozone gas in various industrial environments, and can also be used to detect ozone gas in operating pipelines, containers, and other settings, and is widely used in pharmaceutical, chemical, municipal, and wastewater treatment industries for ozone generator outlet concentration and ozone generator output measurement.
Ozone analyzer with touch screen operation interface, real-time display of ozone gas concentration, pressure and temperature compensation and display, automatic zero time and manual zero modes can be set—high concentration (g/Nm3) range with flow input function, real-time display of ozone generator output. With two sets of relay signal output, users can freely choose the high alarm point and low alarm point signal output connection. The core component adopts UV long life light source system with high transmittance quartz sheet to ensure the stability of the zero point and prevent the zero point drift from affecting the accuracy of the detection concentration.
Sampling method | Positive pressure sampling , Negative pressure sampling |
Content interface | Ozone concentration , Temperature compensation , Pressure compensation |
Light source life | About 30000-50000 hours |
Display interface | 4.3 inch touch screen operation interface |
Auxiliary functions | Temperature compensation, pressure compensation |
Sampling flow rate | 0.5L±0.2L/min |
Input pressure | <0.1MPa |
Concentration error | < 2%FS |
Linearity error | < 2%FS |
Zero point drift | <±0.8%.FS |
Response time | 0.03 seconds for signal, 0.3 seconds for display |
Ambient temperature | -20~50℃. |
Sampling interface | Bypass sampling Φ6 (6*4mm quick screw interface) , Tandem sampling Φ8 (8*6mm quick screw interface) |
Communication mode | RS-485 |
Output mode | 4-20mA(active) |
Relay signal | High alarm point signal, low alarm point signal. |
Input power | AC 110-220V. |
Instrument size | 133mm (H) × 482mm (W) × 300mm (D), 19" 3U chassis. |
Free warranty | Light source free warranty for 2 years; host free warranty for 2 years (except for oil, water, improper use) |
Standard configuration | Anti-corrosion flow meter , intake filter , ozone exhaust gas destroyer , negative pressure suction air pump |
Tag: Exhaust ozone detector, Ozone detector, Ozone concentration online monitor, Ozone generator manufacturer, Tabletop ozone analyzer, OEM/ODM services