Brand Name :Zetron
Model Number :GasTDL-3100
Certification :CE, ISO13485, ISO9001
Place of Origin :China
MOQ :1
Payment Terms :T/T, D/A, L/C, D/P, Western Union, MoneyGram
Supply Ability :1000 set/month
Delivery Time :3-7 days
Measurement Range :O2: (0~5)%VOL(100% can be customized) CO: (0~100)%VOL CO2: (0~100)%VOL CH4: (0~20)%VOL
Measurement Component :O 2 , CO, CO 2 , CH 4 *
Ex-proof Grade :Exd II CT6
Resolution :0.01% VOL
Working Temperature :(-20~+60)℃
Power Supply :24V DC, 24W
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

In-situ Laser Process Gas Analyzer

OVERVIEW

In-situ laser process gas analyzer GasTDL-3100 is a high-performance laser gas analyzer based on tunable diode laser absorption spectroscopy technology (TDLAS).
With a cross-stack design, GasTDL-3100 can be used for industrial process gas control; The response time is fast, which is generally calculated in seconds in in-situ measurement. It can avoid the time delay caused by sampling measurement. The gas component concentration can be reflected online and in real time.

FEATURES

• Adopts TDLAS technology, no cross-interference from other gas
• In-situ installation, no need for sampling or pretreatment system
• Fast response time(T90≤4s), can reflect the gas concentration in real time
• Real-time online measurement, the gas concentration is not easy to be distorted, and the measurement accuracy is high
• Good adaptability in harsh measurement environments such as high temperature, high dust, high moisture, high corrosion, high flow rate, etc.
• Explosion-proof design, high safety factor
• Simple structure, no consumables or moving parts, maintenance-free

SPECIFICATION

Measurement Component O 2 , CO, CO 2 , CH 4 *
Measurement Principle TDLAS
Measurement Range O2: (0~5)%VOL(100% can be customized)
CO: (0~100)%VOL
CO2: (0~100)%VOL
CH4: (0~20)%VOL
Precision ≤±1%F.S.
Repeatability ≤±1%F.S.
Drift ≤±1%F.S.
Resolution 0.01% VOL
Response time T 90 ≤4s
Working Parameter
Ex-proof Grade Exd II CT6
Installation Method In-situ Installation
Working Temperature (-20~+60)℃
Power Supply 24V DC, 24W
Purge Gas Source (0.3~ 0.8) Mpa Industrial N2
Interface Signal
Communication RS485,RS232
Analog signal 2 channels 4~20mA output
3 relay outputs

APPLICATION

Metallurgy Blast furnace ironmaking Blast furnace gas analysis CO, CO 2 , O 2 , CH 4
Safety control of blast furnace coal injection O 2 , CO
Hot blast stove flue gas analysis O 2 , CO
Converter steelmaking Converter gas recycle O 2 , CO
Converter gas safety control About 2
Carbon determination of converter flue gas CO, CO 2 , O 2
Coking production Electric coke catching safety control CO, O 2
Analysis of Coke Dry Quenching (CDQ) Circulating Gas CO, CO 2 , O 2
Coke oven gas analysis H 2 S, NH 3
Other Gas calorific value analysis CO, CH 4
Boiler flue gas analysis CO, O 2
Petrochemical Oil refining Catalytic Cracking (FCC) regeneration
flue gas analysis
CO, CO 2 , O 2
Hydrogen production from alkanes CO, CO 2 , CH 4
Sulfur recovery About 2
Ethylene cracking Reactor outlet, etc. CO, CO2 etc
EO / EG Process gas O2, C2H4 etc
ON Process gas About 2
PP Process gas About 2
Ethylbenzene/styrene monomer/PS Process gas O2, CO/ CO2 trace water in Benzene
PTA Oxidation reactor control CO, CO 2 , O 2
Coal gas Process gas About 2
Methanol/synthetic ammonia/urea Process gas O2, CO, CO2, NH3 etc
Carbon ratio of urea to ammonia NH 3 , CO 2
Chlor-alkali/PVC Trace water in Cl2 H 2 O
Trace water in EDC H 2 O
Synthetic cycle gas O2, CO2, C2H4 etc
Oxychlorination process O2, CO2, C2H4 etc
VCM tail gas recycle About 2
Hydrogen peroxide Oxidation process About 2
Acid production with Sulfuric Oxidation process About 2
TDI Water gas About 2
Environmental protection Flue Gas Emission Analysis of flue gas from waste incineration HCL, HF, CO, CO2, O2
Flue gas denitration process control NH3, NO, NO2
Combustion process control O 2 , CO, CO 2
Cement Cement Production Control of the combustion process at the inlet and outlet of the rotary kiln O 2 , CO, CO 2
Coal injection (mill, pulverized coal silo) safety monitoring O 2 , CO
Combustion control of preheater and cyclone heater O 2 , CO, CO 2
Electricity Thermal power generation Combustion control O 2 , CO
Coal injection (mill, pulverized coal silo) safety monitoring O 2 , CO

Fast Response Fixed Multi Gas Detector O2 CO CO2 CH4 In Situ Laser Process Gas Analyzer

FAQ


Q: When do you reply to messages?
A: We will reply you for your inquiry in 24 hours.

Q: When do you send the products? And how do you send it ?
A: For the small order, we will send out the goods with 5 days,If have stock ,we will send immediately.
We send them by ups, fedex, tnt or dhl. For big order, normal is 20 days will finish.

Q:Do you accept OEM or revised logo, color, model,size?
A:Yes, we accept OEM for the qualify buyer. We can make the products according to customer personal requirement.

Q: How about the quality of the managements ?
A: We have a complete quality control system , all of our products will be fully pre-inspection by QC departments before ,shipping to you . We have the certification of ISO,CE we could send the certification test of our company to you.

Q: How about your after-sale service?
A: After sending, we will track the products for you , until you get the products.
When you got the goods, test them, and give me a feedback.
If you have any questions about the problem, contact with us, we will offer the solve way for you.

Inquiry Cart 0